Zetasizer Lab
Malvern panalytical
Entry-level particle size and zeta potential analyzer with enhanced capabilities
Advantages
The Zetasizer Lab is the perfect entry-level system, offering a wide range of features, including:
- DLS analysis: particle size measurements from 0.3 nm to 10 μm
- Extended size range analysis offers improved accuracy for particle sizes above 1 μm, and indicative results above 10 μm (using ZSU1002 Low Volume Disposable Sizing Cell)
- Zeta potential of nanoparticles and colloids using M3-PALS analysis and constant current zeta mode
- Molecular weight using Static Light Scattering at 90°
- Supports use of Low Volume Disposable Capillary Cell for size measurements in sample volumes as low as 3 μL
- Available in Blue Label and Red Label variants:
- Choose Blue Label for routine sample investigation such as metallic colloids, metal oxides and pigments
- Choose Red Label for more challenging sample types, such as proteins, surfactant solutions and low solid content samples
- On-site upgradeability to either Zetasizer Pro or Zetasizer Ultra models
Description
Specification
Applications
Resources
Our entry-level Zetasizer does not compromise on features. The Zetasizer Lab incorporates Adaptive Correlation, M3-PALS and constant current zeta mode. The Zetasizer Lab also ships with ZS Xplorer, easy-to-use analytical software. ZS Xplorer offers instant feedback on data quality, and guidance on how to improve your results.
Particle size and molecular size
Measurement principle | Classical 90° Dynamic Light Scattering |
---|---|
Measurement angle | 90°, 13° (1) |
Measurement range | 0.3 nm to 15 μm (2) |
Minimum sample volume | 3 μL |
Concentration range | Minimum Sample Concentration: Blue Label: 1 mg/mL 15 kDa Protein Red Label: 0.3 mg/mL 15 kDa Protein Maximum sample Concentration: (3) 40% w/v |
Zeta potential
Measurement principle | Mixed-Mode Measurement phase analysis light scattering (M3-PALS) |
---|---|
Size range | 3.8 nm – 100 μm |
Minimum sample volume | 20 μL (4) |
Concentration range | Red Label: 1 mg/mL (5) to 40% w/v (6) Blue Label: 10 mg/mL (5) to 40% w/v (6) |
Sample conductivity range | Maximum: 260 mS/cm |
Static Light Scattering (molecular weight)
Measurement principle | Static Light Scattering with Debye Plot |
---|---|
Molecular weight range | 980 Da – 20 MDa |
Accuracy | +/- 10% typical |
System
Detector | Avalanche Photodiode |
---|---|
Laser safety | He-Ne (633 nm) Blue label: 4 mW Max Red label: 10 mW Max |
Temperature control range | 0°C to 120°C (7) |
Dimensions (W, D, H) | 322 mm x 565 mm x 245 mm |
Weight | 19 kg |
Power | AC 100-240 V, 50-60 Hz, 4.0 A |
Power consumption | Max 100 W, Typical 45 W |
Ambient conditions | +10°C to +35°C, 35 to 80% RH (Non-condensing) |
Interface | USB 2.0 or higher |
- Academia
- Bioscience
- Food and drink
- Nanomaterials
- Paints, inks and coatings
- Pharmaceuticals